Kooltherm K18 Insulated Plasterboard is a super high performance insulated dry- lining plasterboard suitable for mechanical fixing. Buy mm Kingspan Kooltherm K18 Insulated Plasterboard, a premium performance fibre-free rigid thermoset phenolic insulation core bonded to mm. Kingspan Kooltherm K18 Insulated Plasterboard is a premium performance insulation, with a fibre-free rigid thermoset phenolic insulation core with mm .

Author: Galrajas Meztijin
Country: Montenegro
Language: English (Spanish)
Genre: Career
Published (Last): 28 October 2014
Pages: 425
PDF File Size: 1.93 Mb
ePub File Size: 17.54 Mb
ISBN: 640-2-39734-703-7
Downloads: 32844
Price: Free* [*Free Regsitration Required]
Uploader: Dougis

Specifications Thermal conductivity insulant thickness 0. Sheets should be fixed using either drywall screws or suitable galvanised plasterboard nails located at mm centres.

mm Kingspan Kooltherm K18 Insulated Plasterboard | Wall Insulation

These must be long enough to allow a minimum 25 mm penetration of the supporting timber, and be placed not less than 10 mm from the edges of the board and be spaced at mm intervals along all supporting timbers. Send Us An Enquiry. Fixings should be long enough to allow a minimum embedment of 20 mm into the timber. Ensure accurate trimming to achieve close butting joints and continuity of insulation.

Method of test for fire propagation for products Result – Fire propagation index of Fire tests on building performance 1 not exceeding 12 and sub Index i1 not exceeding 6 for rigid phenolic insulation core Test – BS —7: The board should be fully restrained using mechanical fixings.

Search Product Enter keyword. Product Description Used when fixing to solid wall constructions that are susceptible to rain water penetration. Wallpaper should be stripped and surface mounted fittings removed.

Drywall screws or, alternatively, galvanised clout nails, long enough to allow a minimum 25 mm penetration of the timber, should be placed at mm centres and not less than 10 mm from the edges of the board. knigspan

52.5mm Kingspan Kooltherm K18 Insulated Plasterboard – pack of 15

The Reverse Face The reverse facing of K18 Insulated wallboard is a Composite foil facing autohesively bonded to the insulation core during manufacture. Damaged boards or boards that have been in contact with harsh solvents or acids should not be used.

  ASTM D3410 PDF

This reflective, low emissivity surface improves the thermal resistance of any unventilated cavity adjacent to the K Celotex FI range, for underfloor heating. Your basket is empty. Care should be taken not to overdrive screws. Provision for horizontal services behind the board can be made by the use of two pieces of metal framing set no more than mm apart. Fish River Ranger Accommodation Beating the heat. Kooltherm K18 Insulated Plasterboard. Kooltherm K18 Kingspan Kooltherm K18 is a premium performance rigid phenolic insulated dry-lining plasterboard for mechanically fixed dry-lining.

Timbers should be treated where appropriate. Finishing Tapered edged boards allow the employment of standard dry—lining techniques.

The Old Stone House Aged not by years, but by its stories. Used when fixing to solid wall constructions that are susceptible to rain water penetration.

Click items below for pricing structure. For any enquiries, call 1 23 23 1 or send an email to info kingspaninsulation. Where adhesives are employed, soffit boards and boards at window heads should be temporarily supported. These must be long enough to allow a minimum 25 mm penetration of the supporting timber, and be placed not less than 10 mm from the edges of the board and be spaced at mm intervals along all supporting timbers. Premium performance rigid phenolic insulation thermal conductivity as low as 0.

If correctly applied, K18 Insulated Wall Board has an indefinite life. Specifications Useful links Case Studies. Screws should not be sited less than 10 mm from the edges of the board. This method may be used on timber frame constructions or on any dry masonry walls that will support and retain the battens and associated fixings.

  GOEDICKE TRUMPET ETUDE PDF

On existing constructions all surfaces should be clean and free of loose or flaking materials. The R-value will be reduced in the event of the accumulation of dust on the upward facing surfaces and in those cavities that are ventilated. Test – BS —6: Pricing and Where to Buy. Fixing should employ the same method as is used for the plain wall areas.

Kooltherm K18| Insulated Plasterboard | Kingspan | Ireland

Installation is similar to that 1k8 standard plasterboard. Kingspan Insulation New Zealand We’re ready to help. Its durability depends on the supporting structure and the conditions of its use.

Wall mounted fittings such as electrical sockets should be fitted so as to take into account the additional wall thickness. To find out more about the cookies we use, or to change your cookie preferences i. Product Thickness 35, 40, 50, 60, 70, 80, 90 kingdpan Other thicknesses available upon enquiry.

To find out more about the cookies we use, or to change your cookie preferences i. The insulation core is not resistant to some solvent—based adhesive systems, particularly those containing methyl ethyl ketone.

Product Information Contact Us. Method of kinyspan for fire propagation for products Result – Fire propagation index of Fire tests on building performance 1 not exceeding 12 and sub Index i1 not exceeding 6 for rigid phenolic insulation core.

The screws should be driven straight until the heads are slightly below the paper surface of the plasterboard facing. You might also consider Celotex PL range which is a cheaper product with similar performance spec.