View and Download Gossen MetraWatt PROFISIX instruction manual online. hand-held exposure meter. PROFISIX Measuring Instruments pdf manual. You have an older device from GOSSEN? Here you can find the corresponding operating instructions for previous devices in the field of PROFISIX. Condition: Good The guide is in a good condition, edgewear, minor tear, and scratches on the cover. The inside leaves.

Author: Vugul Arashigar
Country: Canada
Language: English (Spanish)
Genre: Personal Growth
Published (Last): 8 April 2006
Pages: 77
PDF File Size: 17.77 Mb
ePub File Size: 11.35 Mb
ISBN: 669-6-47420-405-1
Downloads: 29380
Price: Free* [*Free Regsitration Required]
Uploader: Brataur

Discussion in ‘ Lighting ‘ started by JmqxAug 22, It is eminently repairable, although in many cases replacement with another used one may be more cost-effective. The scale is the same. I have used my Profisix since I bought it.

If the voltage is correct but the amplification is wrong, the null position will work and the other settings MIGHT work depending on the change. Aug 22, 1.

Gossen PROFISIX instruction manual, user manual, PDF manual, free manuals

In spite of mechanical display and “computer” dial, these meters are electronic as circuitry to store the light reading is necessary for flash measurement. And while it seems to be right, it often won’t proofisix my other meter. Pointer needle with mechanical computer Sensor: Profiwix in combination with a Minolta Spotmeter I am mostly shooting 8x Yes, my presbyopic eyes like my Luna Pro.

  EXFO OTDR MANUAL PDF

I bought my meter second hand so I have not had it since it was new.

Gossen Profisix Problems. . . ? | Photography Forums

Flash metering was incorporated, however sensitivity was reduced compared mahual the Profisix as was the range of accessories Profisix accessories will not fit the Lunasix F. I have alwasy assumed that my Profisix worked the way others did mine is serial 3D Gossrn a few years though. Amazon Music Stream millions of songs. A far more likely explanation is that it’s faulty, no-ones saying you wrong.

Example of complete set. The electronics shut off after 30 seconds. Since we are both getting correct exposure I don’t think you would have continued yours for 25 years if you didn’t.

The Profisix, known as the Luna Pro SBC in some countries, is an excellent meter with reflected and incident capabilities. But that’s a matter of taste. One would expect it to be off in all but one at least type of reading if it is a faulty meter. Amazon Renewed Refurbished products manuap a warranty. I wish there would be this device but in the same size as the smallest possible meters.

Gossen MetraWatt PROFISIX Instruction Manual

The problem with this approach is that if you do not have the necessary precision in the first place all you do is multiply the error without gaining control. Together with the adapters the Profisix forms a complete light measurement system.

  GODARD ALLEGRETTO PDF

Maybe not 10 years, but it has been so long that I can’t remember when it was last changed. Exposure settings are then read from the computer dial, the lower window of which displays the measured EV “Exposure Value”. That is why I am not totally convinced that it is a broken meter.

Adjust the ratio and you have adjusted the movement. Shopbop Designer Fashion Brands.

Share This Page Tweet. Having the odd one or two attachments greatly enhances the capability of the meter, as well as making some things more easy when measuring.

You must log in or sign up to reply here. It may just be a very simple adjustment is needed. Flickr image Meters Gossen. Maybe Gossen made different meters or you could have this changed later.

In the mean-time I have an interesting read about incident meters in BTZS book in measuring the scene brightness range.